Chapter
6
Operating Instructions
CLX490 Compact OMNI Scanner
6-10
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Operation
Parameterization the event-controlled focus control (alternative):
Action Settings
1. Activate focus control func-
tion (choose trigger source)
Ö
R
EADING
C
ONFIGURATION
tab
Ö
F
OCUS
C
ONTROL
– Inputs/Serial or
– Timer or
– Static/No Trigger
2. Choose focus switchover
point (referred to reading
pulse)
F
OCUS
C
ONTROL
Ö
Inputs/Serial
– Immediate or Synchronous
– Latched
3. Set up focus control
D
ISTANCE
C
ONFIGURATION
Ö
Distance Configuration
– Focus Position
Ö
Assignment Table
– Index
– Valid Configurations
4. In I
NPUTS
/S
ERIAL
trigger
mode: choose function for
"IN 4" switching input
Ö
D
EVICE
C
ONFIGURATION
tab
Ö
A
SSIGNMENT
IN 4
– Focus Control
Table 6-5: Guide: Parameterizing the event-controlled focus control