Chapter
10
Operating Instructions
CLX490 Compact OMNI Scanner
10-46
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Appendix
Standard decoder
Tried-and-tested
Ö
decoder from the CLV product family. Suitable for applications with an
adequate code height, limited tilt, and high-quality code prints.
Storage in the CLX
The application-specific
Ö
parameter set can be stored temporarily or permanently in the
CLX. If it is stored temporarily in the RAM, it is lost as soon as the power supply is switched
off. Parameter sets that are stored permanently are transferred to the EEPROM in the CLX
and remain active as the current data record when the power supply is switched off. The
default setting is not affected by this and is stored in a read-only memory (ROM).
Switching sequence
Focus control function for event-controlled switching. Sequence of focus position settings
with associated depths of field. The numbers of the active
Ö
distance configurations are en-
tered at the required position in the assignment table for this purpose.
System messages
Messages
Ö
in plain text used to output the operating status of the CLX. The messages
are output on the auxiliary interface only and can be displayed in extended mode in the T
ER
-
MINAL
E
MULATOR
of the "CLV-Setup" program.
Teach-in
Method of programming the information required to adjust the CLX to the reading applica-
tion in Parameterization mode. Example: teaching in the background for the Autofocus func-
tion, also known as a
Ö
distance profile.
Terminator
Data block in the reading result on the
Ö
host interface. Used to terminate the data content
of the bar code. Contains up to 10 elements, consisting of reading diagnosis data and/or
constants (control characters, letters, digits), depending on the configuration. The "Termina-
tor" block is empty in the default setting of the CLX.
Upload
Method of transferring the
Ö
parameter set from the CLX to the PC
Ö
using the CLV-Setup
program. CLV-Setup either transfers a complete copy of the current parameter set from the
memory (RAM) of the CLX (U
PLOAD
TO
CLV) or just the parameter previously processed using
the context menu of the right mouse button (U
PLOAD
P
ARAMETER
) or all parameters of the dis-
played tab (U
PLOAD
P
ARAMETERS
OF
THIS
V
IEW
). Displays the current parameter values on the
tabs. Prerequisite for modifying the current parameter set.
User interface
Windows-based PC software "CLV-Setup" for operating and configuring the CLX.