Chapter
3
Operating Instructions
CLX490 Compact OMNI Scanner
3-2
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Product description
– For connecting
two
CLX:
AMV30-071 (no. 1017391) for 18 to 30 V DC, enclosure rating max. IP 54
AMV200-011 (no. 6021106) for 18 to 30 V DC, enclosure rating max. IP 65
– or –
Alternatively, a non-SICK Power pack with a voltage output of
18 to 30 V DC
(functional
extra-low voltage pursuant to IEC 364-4-41) and a minimum power output of
20 W
.
Cable no. 2020264 (3 m) with 15-pin D Sub HD connector and one open end for
connecting the CLX to the non-SICK Power pack (supply voltage).
2.
The following operating voltages/power output values:
– AMV60-011: 18 to 30 V DC (to IEC 364-4-41), min. 20 W
– AMV30-071: 18 to 30 V DC (to IEC 364-4-41), min. 40 W
– AMV100-011: 18 to 30 V DC (to IEC 364-4-41), min. 20 W
– AMV200-011: 18 to 30 V DC (to IEC 364-4-41), min. 40 W
– AMS60-013: 230 V AC
±
10 % 50 Hz
– AMS60-012: 115 V AC
±
10 % 50 to 60 Hz
3.
Fitting cables see
Chapter 5.2.2 Prefabricated cables (overview), Page 5-2
.
4.
Appropriate incremental transmitter for tracking.
5.
With external clock pulse supply via the "Sensor" switching input: a suitable reading
pulse sensor for signaling an object with a bar code, e.g. a photoelectric reflex switch.
6.
With object distance detection via the "IN 0 to IN 4" switching inputs: suitable sensors
for multi-stage dynamic focus control, e. g. photoelectric reflex switches.
7.
A higher-level computer (host) with a data interface of type RS 422/485 or RS 232.
8.
A PC (min. Pentium II, 350 MHz, 64 MB RAM, CD drive, a serial port (COM x), mouse
(recommended)) with Windows 95
TM
/98
TM
, Windows NT
TM
, Windows 2000
TM
or
Windows XP
TM
.
9.
A 3-core RS 232 data cable (null modem cable) with two 9-pin D Sub sockets for con-
necting the PC to the auxiliary interface of the CLX in the connection module, e. g.
no. 2014054. Pin 2 (RxD) and Pin 3 (TxD) are crossed.
10. An HTML browser, e. g. Internet Explorer
TM
, for using the online help system CLV-Setup
Help.
11. The appropriate bus connection module BMV/BMH10 (available on request) for con-
necting the CLX to the Interbus-S, Profibus DP, Device Net or the Ethernet.
12. For connection of the CLX to the CAN bus: the operating instructions "Using the CAN
interface" (no. 8009180, English version)
CLX with heater
The following are required to start up and operate the CLX with heater:
1.
A SICK Connection Module from the
AMV100
or
AMV200
series to provide the power
supply and connect the data and function interfaces.
Available types:
– For connecting one CLX: AMV100-011 (no. 6021105) for 24 V DC, max. IP 65
– For connecting two CLXs: AMV200-011 (no. 6021106) for 24 V DC, max. IP 65
– or –
Alternatively, a non-SICK Power pack with a voltage output of 24 V DC +20 %/–10 %
(functional extra-low voltage pursuant to IEC 364-4-41) and a minimum power output
of
100 W
.
Cable no. 2020264 (3 m) with 15-pin D Sub HD connector and one open end for
connecting the CLX to the non-SICK Power pack (supply voltage).