Chapter
10
Operating Instructions
CLX490 Compact OMNI Scanner
10-30
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Appendix
Entering the bar code using the Terminal Emulator function in CLV-Setup
1.
Click
on the toolbar.
The Terminal Emulator is launched.
The CLX is in Reading mode.
2.
Click the E
XTENDED
radio button in the T
ERMINAL
M
ODE
section.
The start and stop characters used by the Terminal Emulator are displayed at the top
of the screen, on the left and right of the text input field.
shows the Terminal Emulator window in extended mode.
3.
Use the drop-down lists to set the start and stop characters to NUL.
4.
Enter the data content of the bar code (character string) on the keyboard.
Use the backspace key to correct any input errors.
The data content must not contain control characters.
5.
Press the [RETURN] or [ENTER] key.
The CLX then interprets all further characters as a new data string.
CLV-Setup sends the character string to the CLX and deletes the entry in the text field.
The CLX does not send an echo.
6.
Once the active reading pulse has ended, the CLX sends the data received from the PC
to the host via the host interface.
Fig. 10-16: CLV-Setup: auxiliary input on the Terminal Emulator