10.3.2
Installation and electrical connection
The pin assignments for the connection cables of the parameter memory no. 2020307/no.
and
¾
Mount the parameter memory on the CLX as shown in
and connect the cables to the AMV/S60 Connection Module.
The color assignment of the wiring for the open ends of the connection cables for the
parameter memory no. 2020981 is shown in
and
.
¾
Mount the parameter memory on the CLX as shown in
and connect the cables to the external power supply.
10.3.3
Operation
The parameter memory connected to the CLX is accessed
•
using the selected CLX start option
•
after the parameters have been downloaded to the CLX with the permanent storage
function and the S
TART
WITH
E
XTERNAL
P
ARAMETERS
option
The start option is set at the bottom right of the D
EVICE
C
ONFIGURATION
tab as shown in
(red frame). The S
TART
WITH
E
XTERNAL
P
ARAMETERS
option is selected by default.
Start with internal parameters
When it starts, the CLX loads the internal parameter set to its RAM.
The "Device Ready" LED lights up constantly.
Since the data is stored permanently, it is not lost when the device is switched off.
Start with external parameters (default setting)
When it starts, the CLX loads the external parameter set to its RAM.
The "Device Ready" LED blinks for approx. 10 s and then lights up constantly.
The data in the CLX is lost when the device is switched off.
Fig. 10-8:
CLV-Setup: "Device configuration" tab with the CLX start options