APPX
Appendix 2 Standards
131
A
Considerations for complying with EC directive
Considerations when using FX5-SF-MU4T5 or FX5-SF-8DI4
When using FX5-SF-MU4T5 or FX5-SF-8DI4, attach a ferrite core to the power cable of a CPU module.
Make 3 turns around the ferrite core and attach within approximately 200 mm from the terminal block and connectors of the
power cable. (Ferrite core used in Mitsubishi Electric's test: E04SR401938 manufactured by SEIWA ELECTRIC MFG. CO.,
LTD.)
Machinery directive
Compliance with the Machinery Directive, which is one of the EU directives, has been mandatory for safety products sold
within EU member states since 1995. Based on the certification by a third-party certification organization, TUV SUD, we
declare that FX5-SF-MU4T5s and FX5-SF-8DI4s comply with the Machinery Directive and affix the CE marking on them.
The sales representative in EU member states is:
Company: MITSUBISHI ELECTRIC EUROPE B.V.
Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
Measures to comply with the machinery directive
The Machinery Directive (2006/42/EC) requires that machinery satisfy the three pillars of safety: mechanical safety, electrical
safety, and worker safety. FX5-SF-MU4T5s and FX5-SF-8DI4s comply with the Machinery Directive. Before using this
product, please read this manual, the relevant manuals, and the safety standards carefully and pay full attention to safety to
handle the product correctly. The descriptions are based on the requirements of the Machinery Directive and the harmonized
standards. However, they do not guarantee that the entire machinery constructed according to the descriptions complies with
the Machinery Directive. The manufacturer of the machinery must determine the testing method for compliance and declare
conformity to the Machinery Directive.
■
Machinery Directive related standards
Immunity requirements
Standard: EN61326-3-1:2008
Test item
Test description
Value specified in standard
EN61000-4-2
Electrostatic discharge immunity
An electrostatic discharge is applied to the
enclosure of the equipment.
• 8 kV air discharge
• 4 kV contact discharge
EN61000-4-3
Radiated, radio-frequency, electromagnetic field
immunity
An electric field is radiated to the product.
80% AM modulation @1 kHz
• 80 M to 1 GHz: 10 V/m
• 1.4 G to 2.0 GHz: 3 V/m
• 2.0 G to 2.7 GHz: 1 V/m
EN61000-4-4
Fast transient/burst immunity
Burst noise is applied to power lines and signal
lines.
• AC power: 3 kV
• DC power: 3 kV
• I/O signal/control: 2 kV
• Functional earth: 2 kV
EN61000-4-5
Surge immunity
Lightning surge is applied to power lines and signal
lines.
• AC power: 2 kV/cm, 4 kV/cm
• DC power: 1 kV/cm, 2 kV/cm
• I/O signal/control: 2 kV/cm
EN61000-4-6
Conducted RF immunity
High-frequency noise is applied to power lines and
signal lines.
0.15 M to 80 MHz
80% AM modulation @1 kHz, 10 V rms
EN61000-4-8
Power-frequency magnetic field immunity
The product is immersed in the magnetic field of an
induction coil.
50Hz/60Hz, 30A/m
EN61000-4-11
Voltage dips and interruptions immunity
Power voltage is momentarily interrupted.
• 0%, 1 period
• 0%, 250/300 periods (50/60 Hz)
• 40%, 10/12 periods (50/60 Hz)
• 70%, 25/30 periods (50/60 Hz)
EN61000-4-29
Voltage dips and interruptions immunity
Power voltage is momentarily interrupted.
• 40% UT 10ms
• 0% UT 20ms
Содержание MITSUBISHI ELECTRIC MELSEC iQ-F FX5
Страница 2: ......
Страница 29: ...1 OVERVIEW 27 1 MEMO ...
Страница 40: ...38 3 PROCEDURES BEFORE OPERATION MEMO ...
Страница 90: ...88 5 SYSTEM CONFIGURATION MEMO ...
Страница 112: ...110 7 PARAMETER SETTINGS 7 1 Refresh Setting MEMO ...
Страница 117: ...9 COMMISSIONING 9 2 Considerations for Inspection 115 9 MEMO ...
Страница 169: ...APPX Appendix 6 How to Use MELSEC iQ F Series Safety Extension Module Configuration Guide 167 A MEMO ...
Страница 171: ...I 169 MEMO ...
Страница 175: ......