6 WIRING
6.5 Installation of Muting Sensors
Sequential muting
In the following example, the material moves from left to right.
As soon as the muting sensors A1 and A2 are activated, a protection function provided by the protective equipment (ESPE) is
temporality disabled.
The protection function remains disabled until one of the sensors within the muting sensors B1 and B2 is enabled again.
Precautions
• When using four muting sensors, connect two muting sensors each to an input of the FX5-SF-MU4T5. Take into account
that the muting sensors are combined as follows: A1 and B2, A2 and B1.
• Only high-side switching sensors can be used for four muting sensors. Check that "HIGH" always overwrites "LOW".
Additionally, use the muting sensors after analyzing risks and errors properly.
(1): Hazardous area
S1: Distance between internal sensors (the sensors are placed symmetry within the ESPE detection line)
S2: Distance between external sensors (the sensors are placed symmetry within the ESPE detection line)
S3: Length of the material
S
2
S
1
S
3
ESPE
(1)
A
1
A
2
B
2
B
1