7.3
Reset and external device monitoring (EDM)
Overview
Reset and external device monitoring can be configured at the safety light curtain
miniTwin4.
!
OSSD1
EDM
k2
24 V DC
k1
0 V DC
K1
K2
OSSD2
Figure 56: Reset button and external device monitoring (EDM)
!
Reset button
•
Resetting is configured through a certain cycle of actuation of the reset button.
•
External device monitoring (EDM) is automatically configured through correct
wiring of the input with the contactors during the first switching of the OSSDs.
•
Each twin stick is configured separately.
Further topics
•
•
"External device monitoring (EDM)", page 34
•
"Configuring external device monitoring (EDM)", page 65
7.3.1
Configuring reset
Overview
To activate the reset function, a reset button must be connected to the safety light cur‐
tain.
You have 4 min for configuring the function after switching on the safety light curtain.
Otherwise the system completely locks 4 min after switching on (lock-out).
Important information
DANGER
Hazard due to unexpected starting of the machine
b
When any work is taking place, use the protective device to secure the machine or
to ensure that the machine is not switched on unintentionally.
7
CONFIGURATION
64
O P E R A T I N G I N S T R U C T I O N S | miniTwin4
8012624/10OM/2018-08-09 | SICK
Subject to change without notice