Table 2: Meaning of LEDs
Position
LED
Display
Comment
!
OUT
O
Green
O
Red
LED lights up green when protective field is free
(OSSD on).
LED lights up red when protective field is inter‐
rupted (OSSD off).
"
EDM
O
Orange
External device monitoring configured.
Ö
Orange
For the configuration of EDM at the first OSSD sta‐
tus change, the safety light curtain expects the
change from 24 V to 0 V at the multifunctional
input.
Or:
In combination with the ERR-LED
Ö
red: External
device monitoring reports defective contactor
§
COM
O
White
External communication active (e.g. for service)
Ö
White
No optical communication to another twin stick .
Or:
Feedback when deactivating configuration.
$
RES
O
Orange
Reset configured.
Ö
Orange
Reset configured.
Or:
In combination with ERR-LED
Ö
red and EDM-LED
Ö
orange: error with configuration or cabling.
%
ERR
O
Red
Protective field interrupted.
Ö
Red
Error.
&
1, 2, 3, 4, 5
O
Blue
Indication of the alignment quality.
Ö
Blue
In combination with ERR-LED
Ö
red: display of an
error.
o
LED off.
Ö
LED flashes.
O
LED illuminates.
Further topics
•
•
•
"Aligning the twin sticks to one another", page 75
3
PRODUCT DESCRIPTION
18
O P E R A T I N G I N S T R U C T I O N S | miniTwin4
8012624/10OM/2018-08-09 | SICK
Subject to change without notice