Minimum
Typical
Maximum
Response time of single device with
24 or 34 mm resolution
≤
13 ms
Additional response time for cas‐
caded systems (host/guest)
2 ms
Additional response time for cas‐
caded systems (host/guest/guest)
4 ms
Power-down time
1)
80 ms
Power-up delay
200 ms
1)
According to IEC 61496-2.
13.3
Power consumption
Table 21: Power consumption
Protective field height in mm
Maximum power consumption in W
1)
120
2.5
180
2.5
240
2.5
300
3.1
360
3.1
420
3.7
480
3.7
540
4.3
600
4.3
660
4.9
720
4.9
780
5.5
840
5.5
900
6.1
960
6.1
1020
6.7
1080
6.7
1140
7.3
1200
7.3
1)
Power discharged again via the OSSDs depending on the connected OSSD load must be added to the
table values.
13.4
Table of weights
miniTwin4
Table 22: Weight miniTwin4
Protective field height in mm
Weight in g
120
50
180
75
240
95
300
115
360
135
13
TECHNICAL DATA
92
O P E R A T I N G I N S T R U C T I O N S | miniTwin4
8012624/10OM/2018-08-09 | SICK
Subject to change without notice