While the telegrams are being executed, a dialog box appears in
which you need to enter the device address of the sensor:
•
Enter the device address of the desired sensor (1 to 4) and
PLS as the device type.
•
Click on OK.
A second dialog box appears in which you need to enter the
device address of the LSI:
•
Enter the device address as zero and LSI as the device
type.
•
Click on OK.
The fault memory and the sensor status of the PLS are read,
and the result log is displayed in the box at the bottom of the
screen.
You can find out what the sensor fault codes mean from the
technical description of the PLS.
•
Rectify the fault and reset the LSI system as described
below:
In case of PLS fault:
•
Switch the power to the PLS off and then back on again.
Then choose
LSI - Initialize
from the menu to reset the LSI
system.
In case of LSI fault:
•
Choose
LSI - Initialize
from the menu to reset the LSI
system.
Or execute the Reset and initialization telegram in the SICK
diagnosis. The LSI system is restarted.
Deconfigure sensor
A sensor which was connected up to a LSI system is
programmed for operation on a LSI. Before disconnecting it from
the LSI and to enable it to be used on its own, you must
deconfigure it by means of the SICK diagnosis.
•
From the menu choose
LSI - SICK Diagnosis
and enter zero
as the device address and LSI as the device type, as
described above. Click on OK.
The Run Diagnosis dialog box appears.
•
Insert the following telegrams in sequence in the list of
telegrams to be executed:
Switch mode: Setup mode
LSI mode on/off: LSI mode OFF
•
Click on Run.
All connected sensors are deconfigured. You can disconnect
them from the LSI and use them on their own.
Note:
If you want to use sensors without LSI, follow the instructions
given in the technical description of the PLS.