AN2 – Tilt angle
Tilt angle for 1D and 2D codes [in degrees] rela-
tive to the horizontal
MCR – Ratio between image and MC [in %]
Relationship between images that have been
taken and successful multireads
X2D – X 2D
Symbol size (number of modules) in X direction;
for 2D codes only
Y2D – Y 2D
Symbol size (number of modules) in Y direction;
for 2D codes only
MX2 – Module X size
Average module size in X direction in mm; for 2D
codes only
MY2 – Module Y size
Average module size in Y direction in mm; for 2D
codes only
IV2 – Inverse (boolean)
Code was read inversely
MD2 – Mirrored (boolean)
Code was read as a mirror-image
CTG – ISO 16022/ISO15415 Symbol contrast
grade
Grading for symbol contrast in accordance with
ISO/IEC16022 and ISO/IEC15415. Checks the
contrast between dark and light dots in the
code.
CTV – ISO16022/ISO15415 Symbol contrast
value
Value for symbol contrast in accordance with
ISO/IEC16022 and ISO/IEC15415. Checks the
contrast between dark and light dots in the
code.
More… Description
PGG – ISO16022/ISO15415 Print growth grade Grading for print growth in accordance with ISO/
IEC16022 and ISO/IEC15415. Checks the diffe-
rence between the ideal and actual dot size. The
value is output in accordance with the values
defined in ISO/IEC16022 and ISO/IEC15415.
PGV – ISO16022/ISO15415 Print growth value
Value for print growth in accordance with ISO/
IEC16022 and ISO/IEC15415. Checks the diffe-
rence between the ideal and actual dot size. The
value is output in accordance with the values
defined in ISO/IEC16022 and ISO/IEC15415.
ANUV – ISO16022/ISO15415 Axial non-unifor-
mity value
Value for axial non-uniformity in accordance with
ISO/IEC16022 and ISO/IEC15415. Checks the
ratio between the code length and width. If the
code is stretched or compressed in terms of its
length or width, it is given a poor rating for its
axial non-uniformity.
ANUG – ISO16022/ISO15415 Axial non-unifor-
mity grade
Grading for axial non-uniformity in accordance
with ISO/IEC16022 and ISO/IEC15415. Checks
the ratio between the code length and width. If
the code is stretched or compressed in terms of
its length or width, it is given a poor rating for its
axial non-uniformity.
UECV – ISO16022/ISO15415 Unused error cor-
rection value
Value for unused error correction in accordance
with ISO/IEC16022 and ISO/IEC15415. Checks
how much redundant data had to be used during
the reading to decode the data content. The best
grade is achieved if redundancy was not
required at all.
More code-related data…