Parameters
5.2.1
Change reading distance
parameter is activated, the reading distance is modified
using the A
UTO
-S
ETUP
function. The function is called up using the buttons on the LEC-
TOR
®
620.
5.2.2
Change camera settings
If the
parameter is activated, the brightness and contrast are mo-
dified using the A
UTO
-S
ETUP
function. The function is called up using the buttons on the LEC-
TOR
®
620.
5.2.3
Change code settings
parameter is activated, the code settings for the D
ATA
M
ATRIX
symbology are modified using the A
UTO
-S
ETUP
function. The function is called up using the
buttons on the LECTOR
®
620.
5.3
Function buttons
The
contains the parameters for defining the functions of the buttons on
the LECTOR
®
620.
5.3.1
Function
parameter to define the function and behavior of the buttons on the
LECTOR
®
620.
• N
O
FUNCTION
: The function buttons on the LECTOR
®
620 are deactivated. As a result, you
can avoid malfunctions during operation caused by pressing the buttons by accident.
• T
RIGGER
AND
AIMING
LASER
: You can use the buttons on the LECTOR
®
620 to carry out a rea-
ding without the LECTOR
®
620 having to be connected to the PC.
- You use the left button to open the reading gate. The reading gate remains open until the
button is released again or until the condition for closing the reading gate has been met.
- You use the right button to turn the aiming laser on/off. The aiming laser is automatically
turned off after 5 minutes.
• M
ENU
(
SAVE
PERMANENT
): The buttons on the LECTOR
®
620 have a menu function and can
be used for parameterization. The changed parameter values are permanently stored in the
device. Existing values are overwritten.
• M
ENU
(
SAVE
TEMPORARY
): The buttons on the LECTOR
®
620 have a menu function and can
be used for parameterization. Existing values are initially overwritten. The changed parame-
ter values are retained and stored in the device until the device is restarted. As the old pa-
rameter values are restored after the restart, this setting is useful for testing parameter
changes. The function can also be used to temporarily read another code and reset the set-
tings by restarting the device.