ONLINE HELP SOPAS
Chapter
5
LECTOR®620
Parameters
8013778/Y269/2013-11-27
©
SICK AG · Germany · All rights reserved · Subject to change without notice
133
5.10.10.1.3
Device ID
parameter displays the device ID that was assigned under
. The device is assigned a unique number in the network in the form of the device ID.
The assigned ID is used as a CAN node for the CAN bus.
The device must be clearly identified on the network to enable communication via CAN bus
and to assign reading results to devices.
5.10.10.1.4
Data transmission rate
The maximum transmission rate can be adjusted via the
The value is provided in bits/s.
All devices in the CAN network must be operated at the data transmission rate. The ma-
ximum length of cable for the network is dependent on the data transmission rate.
5.10.10.1.5
Output format
An output format is assigned to the interface via the
Output formats are defined under
.
5.10.10.1.6
Enable heartbeat
If the
parameter is activated, a signal is output via the interface at regular
intervals (
). The availability of the reading device can therefore be chek-
ked via the interface.
5.10.10.1.7
Heartbeat interval
parameter is used to define the time between the heartbeat signals
in seconds.
5.10.10.1.8
Restart interval on sending
parameter is activated, the time between the heartbeat
signals starts again after output of the reading results.
5.10.10.1.9
Mask for digital input
A filter for the digital input bits that is used to integrate the device into a second fieldbus for
assigning the data is entered via the
parameter.
Example: All bits are active when 0xFFF is entered.
To assign the digital CAN input bits, see
.