Parameters
5.10.10.1.10 Enable digital output
parameter is activated, the device's reading diagnosis data is
monitored by the control via the CANopen interface. The reading device initiates monitoring
via process data objects (PDOs). The device sends a PDO with identifier 0x180 and CAN
node to indicate that the control should load an entry.
5.10.10.1.11 COB ID RPDO digital input
parameter defines the CAN identifier for the receive process
data objects (RPDOs) received on the reading device.
For additional information see the F1 help.
The CAN input bits on the reading device are to be assigned to the CANopen object dictio-
nary as follows:
•
Byte 0: 0x6200 / 01
•
Byte 1: 0x6200 / 02
Assignment of the digital CAN input bit for the 0x6200 object on the reading device:
To activate the switching functions, the Fieldbus input value must be set with the corre-
sponding parameters. If, for example, the trigger bit is to be used for controlling the trigger,
the Fieldbus input value must be set as the start of the object trigger (see
).
Bit
Assignment
Name
Remark
Byte 0, Bit 0 Fix
Trigger
LSB
Byte 0, Bit 1 Fix
Sensor – Idle
Byte 0, Bit 2 Fix
TeachIn1
Byte 0, Bit 3 Fix
TeachIn2
Byte 0, Bit 4 Fix
External Output_1
Physical Output 1 of
CDF600
Byte 0, Bit 5 Fix
External Output_2
Physical Output 2 of
CDF600
Byte 0, Bit 6 Fix
Digital Output_1
(Result_1)
Byte 0, Bit 7 Fix
Digital Output
(Result_2)
Byte 1, Bit 0 Soft
PLC_Out_08
Byte 1, Bit 1 Soft
PLC_Out_09
Byte 1, Bit 2 Soft
PLC_Out_10
Byte 1, Bit 3 Soft
PLC_Out_11
Byte 1, Bit 4 Fix
Distance_Config_0
LSB
Byte 1, Bit 5 Fix
Distance_Config_1
Byte 1, Bit 6 Fix
Distance_Config_2
Byte 1, Bit 7 Fix
Distance_Config_3
MSB