Chapter
5
ONLINE HELP SOPAS
LECTOR®620
60
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8013778/Y269/2013-11-27
Parameters
5.7.9.2.1
Code length
parameter to restrict the permitted number of characters in a
code.
• F
REE
: Codes of any code length are read.
• I
NTERVAL
: The
parameter can be used to define the minimum and maximum code
length. Only codes with a code length between these two values are read.
• F
IXED
: The
parameter is used to define several fixed code lengths. Only codes
with one of these defined code lengths are read.
5.7.9.2.2
Interval
parameter can be used to define the minimum and maximum code length. Only
codes with a code length between these two values are read.
By defining a minimum and maximum code length, you restrict the range of codes to be
read. This can lead to a reduction in the decoding time.
5.7.9.2.3
Fixed length
parameter is used to define several fixed code lengths. Only codes with one
of these defined code lengths are read.
By defining certain permitted code lengths, you restrict the range of codes to be read.
This can lead to a reduction in the decoding time.
5.7.10
Code 93
parameter is activated, decoding is activated for the corresponding code ty-
pe. The configuration tab for the corresponding code type can be seen and opened in
SOPAS ET.
As only activated code types are processed, you can increase the processing speed by
deactivating the code types that are not being used.
• Code name:
(4-value)
• Character set: 43 alphanumeric characters (10 digits, 26 upper-case letters, 7 special
characters: Space, -, ., $, /, +, and %)
• Intrinsic safety: Average
• Spatial requirements: Low
• Standard: ISO/IEC 16388
• Area of application: Parcel and postal service