Chapter
5
ONLINE HELP SOPAS
LECTOR®620
158
©
SICK AG · Germany · All rights reserved · Subject to change without notice
8013778/Y269/2013-11-27
Parameters
5.10.13.4.5
Control
The
parameter is used to choose between configuration with units of length or con-
figuration with units of time.
• T
RACK
CONTROLLED
: The entries for the
parameter are made in mm.
• T
IME
CONTROLLED
: The entries for the
parameter are made in ms.
5.10.13.4.6
Length
If the T
IMER
/T
RACKING
condition is selected under the
parameter, you can use
parameter to enter the duration for which the digital output remains activated.
The unit can be selected in the
parameter.
5.10.13.5 External Output 1
The connection module CDB620 or CDM420 in conjunction with the parameter memory
module CMC600 can be used to extend the number of available digital outputs. The para-
meter memory module CMC is used for output extension and converts a digital signal into
a command. External digital outputs react more slowly than the internal digital outputs of
the LECTOR
®
620.
group contains the parameters for modifying external digital output 1.
5.10.13.5.1
Active
The
parameter is used to select the event for which the digital output is activated.
• SOPAS C
OMMAND
: The output is activated by a command. As a result, the defined statuses
can be displayed via a connected control lamp as a result of a controller (PLC) command.
• D
EVICE
READY
: The output is activated as soon as the LECTOR
®
620 is operational.
• G
OOD
R
EAD
: The output is activated in the event of a successful reading.
• N
O
R
EAD
: The output is activated in the event of an unsuccessful reading.
• T
EACH
-
IN
1 OK: The output is activated if the M
ATCHCODE
T
EACH
-
IN
1 was taught in suc-
cessfully.
• T
EACH
-
IN
1 NOK: The output is activated if the M
ATCHCODE
T
EACH
-
IN
1 was not taught in suc-
cessfully.
• T
EACH
-
IN
2 OK: The output is activated if the M
ATCHCODE
T
EACH
-
IN
2 was taught in suc-
cessfully.
• T
EACH
-
IN
2 NOK: The output is activated if the M
ATCHCODE
T
EACH
-
IN
2 was not taught in suc-
cessfully.
• C
ONDITION
M
ATCH
1: The output is activated if the read code corresponds to the matchcode
from C
ONDITION
M
ATCH
1.
• C
ONDITION
M
ULT
C
ODES
1: The output is activated if the number of read codes corresponds
to the required number from C
ONDITION
M
ULT
C
ODES
1.
• C
ONDITION
T
EACH
I
N
1: The output is activated if the read code corresponds to the match-
code from C
ONDITION
T
EACH
I
N
1.
• C
ONDITION
T
EACH
I
N
2: The output is activated if the read code corresponds to the match-
code from C
ONDITION
T
EACH
I
N
2.