Commissioning the system
6
Commissioning the system
The functionality of the LCUR1411 interface unit can only be checked when the entire
system comprising
Machine/system
LCUR1411
C4000 Standard/Advanced
is connected and configured as per the related operating instructions.
6.1
Configuration of the C4000 Standard/Advanced
After carrying out the necessary steps in chapter 5 “Electrical installation” of these
operating instructions, the C4000 safety light curtain must be configured (see the SICK
operating instructions “C4000 Standard/Advanced Safety Light Curtain”, chapter
“Configurable functions”).
There you will find, e.g., information on the functions
Restart interlock
External device monitoring (EDM)
Blanking — only with C4000 Advanced
Other functions
6.2
Blanking (blanking)
Please note that with the blanking functions, additional steps are necessary during the
electrical installation; optional parts are also required (see chapter 5.4).
You will find detailed instructions on the configuration in the SICK operating instructions
“C4000 Standard/Advanced Safety Light Curtain”, chapter “Configurable functions,
Blanking”).
Teach-in protective field again on changes!
If a protective field changes, e.g. due to changes on the tool used, the protective field must
be taught-in again as per the SICK operating instructions “C4000 Standard/Advanced
Safety Light Curtain” to ensure safe operation. It is also necessary to provide additional
mechanical protective measures in the blanked areas. Finally the safety functions must be
tested (see chapter 7).
From firmware V_3.31 the blanking function can be activated or deactivated again using
the extension plug. As a result two operating modes are possible. These operating modes
must be configured using the software CDS. In the following there is a short description of
the settings necessary in the software.
Please note that this feature is only possible with a C4000 Advanced safety light curtain
and an extension plug. For details on the configuration, please see chapter 6 of the
operating instructions for the C4000 Standard/Advanced.
Note
WARNING
Note