Electrical installation
Designation
Terminal no. on the
AGS with connector
variant
Terminal no. of the
LCUR1-411
Function
L
A4
20
(at 230/115 V AC)
Voltage supply with
230/115 V
N
A5
19
(at 230/115 V AC)
Voltage supply with
230/115 V
PE
PE
21
Earth conductor
+24 V
A1
23
Voltage supply with
24 V
0 V
A2
22
Voltage supply with
24 V
Contact NC
A1
16
Normally closed
circuit with fuse
Contact NC
A2
18
Contact NO
B2
12
Normally open
circuit with fuse
Contact NO
B3
13
Contact NO
C1
14
Normally open
circuit with fuse
Contact NO
C2
15
Selector switch
A8
2
single break PSDI
mode
Selector switch (with
restart interlock)
A6
4
double break PSDI
mode
Selector switch
(without restart
interlock)
A9
3
Implementation via
CDS with C4000
EDM IN
B7
9
External device
monitoring (only if
used previously)
EDM OUT
B6
8
External device
monitoring (only if
used previously)
RESET
C8
6
Implementation via
CDS with C4000
RESET
C7
7
Implementation via
CDS with C4000
MCC IN
C5
11
Machine contact
circuit
MCC OUT
C4
10
Machine contact
circuit