Electrical installation
1.
Carefully place both units on a slip-resistant base with the lenses facing downwards.
2.
Remove the rear panel of the units by loosening the four cross-recessed screws.
3.
Set the required interface type by configuring the DIL switches S 2.3 and S 2.4 on the
additional p.c.b. (
Fig. 5-11
) as shown in
Table 5-8
.
The default setting is
RS 485-2w
(S 2.3 set to ON)
Data transfer rate
Ø
Set the data transfer rate for the RS 485 interface via the DIL switches S 1.1 to S 1.7 as
shown in
Fig. 5-11
. Only set the switch for the desired transfer rate to ON!
The default setting is
187,500 bd
(S 1.4 set to ON).
Ø
Secure the rear panels tightly again before installing the units.
Fig.
5-11: ISD 260/280: Position of the DIL switches for configuring the data interface
1) ISD 260: max. 0.5 MBd, S 1.7 and S 1.8
locked
Interface
DIL switch setting S 1.
DIL switch setting S 2.
ISD 260/280
1
2
3
4
5
6
7
8
1
2
3
4
RS 422
OFF OFF OFF ON OFF OFF OFF OFF
B1
B1
OFF OFF
RS 485 (2-wire)
1)
B2
B2
B2
B2
B2
B2
B2
OFF
B1
B1
ON OFF
RS 485 (4-wire)
B2
B2
B2
B2
B2
B2
B2
OFF
B1
B1
OFF ON
1) Default setting: 187,500 Bd
B1: line termination ON/OFF (see
Chapter 5.2.6
Connecting the data interface
,
Line termination (RS 422/485)
, Page 40
)
B2: Baud rate setting as shown in
Fig. 5-11
, only set one switch to ON!
Tab.
5-8: ISD 260/280: Setting of the DIL switching blocks S 1 and S 2
19 200
9 600
93 750
187 500
375 000
500 000
1,5 M
L 1
Term+
Term–
RS-485-2L
RS-485-4L
S1
1)
S2
ON
OFF
ON
OFF
1
2
3
4
5
6
7
8
Additional p.c.b.
➏
1
2
3
4
Shown switch settings: default (RS 485 2-wire)
Configuration
and
electrical
installation
of
the
ISD
260/280