Chapter
3
Operating Instructions
ICR890 High-end CCD Camera System
34
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011325/0000/2006-10-24
Product description
The illumination is controlled by the camera and can be switched on permanently or for the
duration of the internal reading gate.
If the reading gate does not run to the end due to an error (e. g. when the conveyor system
comes to a halt), the illumination automatically switches off once the settable timeout has
expired. In order to prevent epilepsy, the minimum power-on time of the illumination is 3 s.
The illumination mode and the timeout for the ICI890 Illumination can be configured using
the SOPAS-ET Configuration Software:
P
ROJECT
T
REE
, ICR890, P
ARAMETER
, R
EADING
CONFIGURATION
, L
AMP
C
ONTROL
, register tab
I
LLUMINATION
MODE
Fig. 3-8:
ICR890 System with deflection mirror for reading from above