Electrical installation
5.3
Electrical connections and cables
Prerequisites for enclosure rating IP 64
All the electrical connections of the camera and illumination have been provided with
appropriate protective caps for delivery.
To maintain the enclosure rating IP 64,
unused
connections have to be provided with
protective caps during operation. The connectors attached to used connections have to be
firmly
screwed or engaged.
The same applies to the EMC requirements (ESD) according to CE.
The protective caps have the following colours:
–
M12 connectors: yellow (plugs) and black (sockets)
–
RJ-45 connections: Grey, fixed to the device via a strap (cannot be lost)
–
Power supply: black
RF interference in case of use in residential areas.
¾
ICR890 High-end CCD Camera System is exclusively intended for use in an industrial
environment.
5.3.1
Electrical connections of the ICD890 Camera
The electrical connections of the ICR890 System comprise eleven M12 connectors
attached to the housing of the
ICD890 Camera
(on and next to the panel), two Harting
connectors for the power supply as well as two RJ-45 connections (enclosure rating IP 67)
for the GBit Ethernet.
Abb. 5-4:
ICD890 Camera: Position of the electrical connections (standard system)
Panel
Ethernet
(GBit channels)
Power supply
(IN and OUT)
Ethernet
(host)