Chapter
5
Operating Instructions
ICR890 High-end CCD Camera System
62
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011325/0000/2006-10-24
Electrical installation
5.3.3
Electrical connections of the MSC800 (overview)
Please refer to the
MSC800 Operating Instructions
(no. 8011540) for connections of the
MSC800-0000 logic controller.
The following interfaces are realized via the MSC800-0000 connections:
-
Abb. 5-5:
MSC800-0000 logic controller: Position of the electrical connections
Connection
Design
Number of
poles
Function
PROFIBUS
D-Sub
9, socket
Main data interface
USB 2
USB
4
Auxiliary data interface
ETHERNET 3
RJ-45
8, socket
Auxiliary data interface
ETHERNET 2
RJ-45
8, socket
Auxiliary data interface
USB 1
USB
4
Auxiliary data interface
ETHERNET 1
RJ-45
8, plug
Main data interface
AUX 2
Block
14, terminals Auxiliary data interface
(RS 232, RS 422/485)
AUX 1
D-Sub
9, plug
Auxiliary data interface
(RS 232, RS 422/485)
OUT
Block
14, terminals Digital switching outputs (system status)
IN
Block
12, terminals Digital switching inputs
TRIGGER
Block
12, terminals Digital switching inputs (reading pulse)
INC
Block
12, terminals Digital incremental encoder inputs
HOST (1/2)
Block
14, terminals Main data interface (RS 232, RS 422/485)
CAN 2
Block
12, terminals Input/Output CAN-SENSOR network 2
CAN 1
Block
12, terminals Input/Output CAN-SENSOR network 1
POWER
Block
8, terminals
Power supply input 24 V DC
Tab. 5-9: MSC800-0000 logic controller: Function of the electrical connections (overview)