Subject to change without notice
Assembly and Installation...................................................................... 33
Project planning............................................................................................ 33
3.1.1
Fitting the flange with tube .......................................................... 35
Fitting the MCU control unit ......................................................... 38
Fitting the optional external purge air unit.................................. 40
Assembly work.............................................................................. 41
Fitting the weatherproof cover..................................................... 42
Properly installed power isolating switches............. 43
Lines with correct rating........................................... 43
Grounding the devices.............................................. 43
Responsibility for system safety .............................. 43
General information, prerequisites ............................................. 44
Installing the purge air supply ..................................................... 44
3.3.3.1
Optional external purge air unit ............................... 45
Connecting the MCU control unit................................................. 47
3.3.4.1
Work to be done ....................................................... 47
MCU processor board connections.......................... 48
Connection of connection line to MCU .................... 49
Standard connection ................................................ 50
Connecting the scattered light receiver ...................................... 51
Connecting the MCU remote control unit.................................... 52
3.3.6.1
Connection to the MCU control unit......................... 52
Connection to the MCU remote control unit............ 52
Fitting the interface and I/O module (option) ............................. 53
Start-up and Parameter Settings .......................................................... 54
General information ..................................................................... 54
Installing SOPAS ET ...................................................................... 55
4.1.2.1
Password for SOPAS ET menus................................ 55
Connection to the device via USB line ........................................ 55
4.1.3.1
Finding the DUSTHUNTER COM port........................ 55
Connection to the device via Ethernet (option) .......................... 57
Preparatory work .......................................................................... 58
Scaling the measuring system for transmission measurement. 63
Adjusting the laser beam for scattered light measurement....... 63
Entering application-specific parameters ................................... 64