Operating instructions Distance measuring device DL100 Pro – RS-422
Technical data
84
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
14.7 Outputs
Outputs
Multifunction outputs MF1 and MF2, type: B (push/pull), adjustable
• Hi > UV – 3 V
• Lo < 2 V
→
See page 46, Table 13 and page 52, Table 18 parameter
"ActStat".
Maximum output current
Max. 100 mA
Output load
• Capacity: 100 nF
• Inductive 20 mH
Table 57: Outputs
14.8 Interfaces