8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 55
Operating instructions Distance measuring device DL100 Pro – RS-422
Operation at the measuring device
Menu "SpecFu"
(continued)
Parameter
Description
Heat
Requirements for the display
• Only for versions with heating DL100-xxHxxxxx
This menu is used to set the temperature at which the heating
is to activate. The hysteresis is set firmly to 2 K.
Adjustment range
•
-10 … +40 °C
Factory setting
• -10 °C
FMode
Requirements for the display
• Only for versions with frequency switching DL100-xxxBxxxx
Select frequency range Frequency switching may be required
at parallel placement of several distance measuring devices.
→
Also see page 25, chapter 6.4.
Options
• Mode 1
• Mode 2
• Mode 3
• Mode 4
Factory setting
• Mode 1
Reset
Perform reset
→
Table 20: Menu "SpecFu"
8.6
Perform reset
1. Select the parameter "Reset" in the menu "SpecFu".
→
2. Push the key
.
3. The safety request "Sure?" is displayed.
4. Push the button
to reset the measuring device to the delivery state.
Push the key
to cancel the process.