Operating instructions Distance measuring device DL100 Pro – RS-422
Operation at the measuring device
54
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
8.5.15 Menu "SpecFu"
Set special functions via this menu.
You can get to the menu "SpecFu" via the menu path:
Main menu
→
→
Menu
→
→
RS422
→
→
more
→
→
MFx On
→
→
(MF1
→
→
MF2
→
→)
Offset
→
→
SpecFu
Push the
key for at least 2 seconds to get to the "Menu".
Push the
key so that the parameter "AvgDst" is displayed.
Use the keys
and
to browse within the menu.
Requirements for the display
• Menu "more": Option "On"
Parameter
Description
AvgDst
Select filter depth for the distance values.
Options
• Medium
• Slow
• Fast
Factory setting
• Medium
AvgSpd
Select filter depth for the speed values.
Options
• Medium
• Slow
• Fast
Factory setting
• Medium
ErrRej
Select time for error suppression. During this time, the old
measurement value is output. When there still is no valid
measurement value after the time selected for the parameter
"ErrRej", the value "0" is output.
Options
• 200ms: Error/warning is indicted when the error is present
for longer than 200 ms.
• 50ms: Error/warning is indicted when the error is present
for longer than 50 ms.
•
Off Error/warning is indicated at once, without delay.
Factory setting
• 200ms