Operating instructions Distance measuring device DL100 Pro – RS-422
Operation via Ethernet (Ethernet interface)
66
© SICK AG • Subject to change without notice • 8014753/ZVZ7/2018-03-22
Field "MF2, Threshold distance
underflow"
→
See page 64, Table 36, "MF1, Threshold distance underflow"
Field "MF2, Threshold velocity
exceeded"
→
See page 64, Table 37, "MF1, Threshold velocity exceeded"
Field "MF2, Service configuration"
→
See page 65, Table 38, "MF1, Service configuration"
Field "Number fo MF activation"
Parameter
Description
MF1
Counts the switching events of the multifunction input and
output MF1. You may reset the counters via the button "Reset
MF1".
Read/Write access
• Read and write
Input value
• –2147483648 ... 2147483647
M2
Counts the switching events of the multifunction output MF2.
You may reset the counters via the button "Reset MF2".
Read/Write access
• Read and write
Input value
• –2147483648 ... 2147483647
Table 40:
Page "Parameter settings" – field "Number MF activation"
Field "Advanced device functions"
Parameter
Description
Average filter
distance
Select filter depth for the distance values.
Read/Write access
• Read and write
Input value
• 0: Fast / 1: Medium / 2: Slow
Factory setting
• Medium
Average filter
velocity
Select filter depth for the speed values.
Read/Write access
• Read and write
Input value
• 0: Fast / 1: Medium / 2: Slow
Factory setting
• Medium