Operating instructions Distance measuring device DL100 Pro – RS-422
Operation at the measuring device
Main menu
→
→
Menu
→
→
RS422
→
→
more
→
→
MFx On
→
→
MF1
→
→
Actsta
→
→
Functn
→
→
Preset
Push the
key for at least 2 seconds to get to the "Menu".
Requirements for the display
• Menu "more": Option "On"
• Menu "MFx On": Option "Enable"
• Parameter "Functn": Option "Preset"
Parameter
Description
sPrset
The preset serves as initialization value. When the
multifunction input MF1 is activated, the preset is used.
Adjustment range
• –300000
...
+300000
Since the display only has six digits, you may only enter
negative values up to "–99999" in the display.
Factory setting
• 10
Table 17: Submenu "MF1 – Preset"
1. Select the function "Preset" for the multifunction input MF1.
2. Enter the parameter "Preset" for the desired initialization value.
3. Move the vehicle to the initialization position.
4. Activate the multifunction input MF1, e.g. via a proximity initiator,
photoelectric sensor or switch.
5. The output value of the distance measuring device corresponds to the
value set for "Preset" at the initialization position.