8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 73
Operating instructions Distance measuring device DL100 Pro – RS-422
RS-422 interface
Set baud rate 4.800 Bd
Description
Protocol setup
To the DL100
<STX>022C00<ETX>
From the DL100: OK
<STX>823C00<ETX>
Set baud rate 9.600 Bd
Description
Protocol setup
To the DL100
<STX>022C01<ETX>
From the DL100: OK
<STX>823C00<ETX>
Set baud rate 19.200 Bd
Description
Protocol setup
To the DL100
<STX>022C02<ETX>
From the DL100: OK
<STX>823C00<ETX>
Set baud rate 38.400 Bd
Description
Protocol setup
To the DL100
<STX>022C03<ETX>
From the DL100: OK
<STX>823C00<ETX>
Set baud rate 115.200 Bd
Description
Protocol setup
To the DL100
<STX>022C04<ETX>
From the DL100: OK
<STX>823C00<ETX>
10.3.4 Resolution settings
Adjust resolution 0.1 mm
Description
Protocol setup
To the DL100
<STX>022E00<ETX>
From the DL100: OK
<STX>822E00<ETX>
Adjust resolution 0.125 mm
Description
Protocol setup
To the DL100
<STX>022E01<ETX>
From the DL100: OK
<STX>822E00<ETX>
Adjust resolution 1 mm
Description
Protocol setup
To the DL100
<STX>022E02<ETX>
From the DL100: OK
<STX>822E00<ETX>
Adjust resolution 10 mm
Description
Protocol setup
To the DL100
<STX>022603<ETX>
From the DL100: OK
<STX>822E00<ETX>