Operating instructions Distance measuring device DL100 Pro – RS-422
Operation at the measuring device
8.5.11 Submenu "MF1 – Srvice"
This submenu is used to parameterize the multifunction output MF1 as
service output. You may activate (on) or deactivate (off) several options.
You can get to the menu "Srvice" via the menu path:
Main menu
→
→
Menu
→
→
RS422
→
→
more
→
→
MFx On
→
→
MF1
→
→
Actsta
→
→
Functn
→
→
Srvice
Push the
key for at least 2 seconds to get to the "Menu".
Requirements for the display
• Menu "more": Option "On"
• Menu "MFx On": Option "Enable"
• Parameter "Functn": Option "Srvice"
Parameter
Description
WrnLsr
Activating and deactivating warning messages when the
measuring device must be replaced soon because the laser
ages.
Options
• On
•
Off
Factory setting
• On
WrnLvl
Activate or deactivate warning messages when the damping
value is undercut, e.g. at contamination.
Options
• On
•
Off
Factory setting
• On
WrnTemp
Activate or deactivate warning message when the inner
temperature of the measuring device is outside of the
permissible thresholds.
Options
• On
•
Off
Factory setting
• On