8014753/ZVZ7/2018-03-22 • © SICK AG • Subject to change without notice 53
Operating instructions Distance measuring device DL100 Pro – RS-422
Operation at the measuring device
Submenu "MF2 – Speed"
This submenu corresponds to the submenu "Speed" in the menu "MF1".
→
8.5.14
Menu "Offset"
Set an offset via this menu.
You can get to the menu "Offset" via the menu path:
Main menu
→
→
Menu
→
→
RS422
→
→
more
→
→
MFx On
→
→
(MF1
→
→
MF2
→
→)
Offset
Push the
key for at least 2 seconds to get to the "Menu".
Push the
key. The currently set offset is displayed here.
Requirements for the display
• Menu "more": Option "On"
Value
Description
Offset
Specify offset. The offset is added to the internally determined
measurement value. The offset affects all outputs and the
display indication.
When the "Preset" function is activated, the offset is
overwritten by triggering of the preset input.
Adjustment range
•
-300000 … +300,000 mm
Factory setting
• 0 [mm]
Table 19: M
enu "Offset"