Operating Instructions
Chapter
5
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
5-1
Electrical installation
5
Electrical installation
5.1
Installation sequence
•
Connect the CLV to a SICK Connection Module from the series AMV/S, BMV/BMH 10
or BMS 20, or using a customer-specific wiring configuration
•
Connect the data and function interfaces of the CLV in the module
•
Connect the PC to the Connection Module (at the terminal interface on the CLV)
•
Connect the power supply to the Connection Module
5.1.1
SICK Connection Modules (overview)
CLV Type
Temperatur
range
Connection
module
Purpose
see
chapter
CLV
without
heater
0 ... +40
°
C
AM
V
60
– Connecting
one
CLV
– Operating voltage 18 ... 30 V DC
– Enclosure rating IP 30, max. IP 54
AM
S
60
– Connecting
one
CLV
– Operating voltage 230 V AC (115 V)/24 V DC
– Enclosure rating IP 30, max. IP 54
AMV 100
– Connecting
one
CLV
– Operating voltage 18 ... 30 V DC
– Enclosure rating IP 52,
with connector cover max. IP 65
BMV/BMH 10
Bus Connection
Module
– Connecting
one
CLV to the Profibus-DP, DeviceNet
or Ethernet
– Operating voltage 20 ... 30 V DC
– Enclosure rating IP 52,
with connector cover max. IP 65
BMS 20
Interbus-S
– Connecting
one
CLV to the Interbus-S
– Operating voltage 24 V DC
– Enclosure rating max. IP 54
AMV 30-071
– Connecting
two
CLVs
– Operating voltage 18 ... 30 V DC
– Enclosure rating IP 30, max. IP 54
AMV 200
– Connecting
two
CLVs
– Operating voltage 18 ... 30 V DC
– Enclosure rating IP 52,
with connector cover max. IP 65
CLV
with
heater
– Line scanner
– Line scanner
with oscillating
mirror
AMV 100
– Connecting
one
CLV
–35 ... +35
°
C
– Operating voltage 24 V DC +20%/–10%
–35 ... +35
°
C
– Enclosure rating IP 52,
with connector cover max. IP 65
AMV 200
– Connecting
two
CLVs
– Operating voltage 24 V DC +20%/–10%
– Enclosure rating IP 52,
with connector cover max. IP 65
Table 5-1: Connection Modules for the CLV