Operating Instructions
Chapter
6
CLV 490 Bar Code Scanner
8 008 796/0000/25-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
6-33
Operation
6.6
CLV messages
The CLV outputs system, warning and error messages in English in response to the actions
carried out by the user. The messages are output in plain text via the terminal interface only.
6.6.1
Displaying messages
Proceed as follows in order to display messages on the screen of the PC in the "CLV-Setup"
program:
1.
Click
in the toolbar.
The Terminal Emulator window is then displayed.
2.
In the T
ERMINAL
MODE
section, choose E
XTENDED
.
The CLV then outputs messages in response to events that occur while the bar code is
being read. The messages are only output in the
extended mode
of the Terminal Emulator!
6.6.2
System messages
System messages confirm that an action has been carried out successfully, e. g. changing
the operating mode. The user is not required to carry out any further steps here.
Chapter 10.5 System messages, Page 10-40
explains the contents of the messages.
6.6.3
Warning messages
Warning messages indicate that it was not possible to perform an action or that the values
set for the parameters can cause an error while the bar code is being read.
lists the warning messages in alphabetical order together with the associated
corrective measures.
6.6.4
Error messages
Error messages indicate the following types of error:
•
a device defect
•
incorrect parameter settings
•
errors during data transmission to the host
Chapter 8.3.1 CLV without external parameter memory, Page 8-2
lists the messages in
alphabetical order together with the associated corrective measures.
Message
Meaning
Remedy
"Warning: Master Timeout"
The selected master timeout is too short
Optimize the master timeout using the D
EVICE
C
ONFIGURATION
tab in the user interface of CLV-
Setup. Perform a download to the CLV!
See also
Technical Information "Master/Slave
with Bar Code Scanners",
no. 8 007 675
Table 6-12: Warning messages