System requirements
CLV without heater
The following are required to start up and operate the CLV without heater:
1.
A SICK Connection Module to provide the power supply and connect the data and
function interfaces.
Available types:
– For connecting
one
CLV:
AMV 60-011 (no. 1 017 134) for 18 ... 30 V DC, enclosure rating max. IP 54
AMS 60-013 (no. 1 017 139) for 230 V AC 50 Hz/24 V DC,
enclosure rating max. IP 54
AMS 60-012 (no. 1 017 140) for 115 V AC 50/60 Hz/24 V DC,
enclosure rating max. IP 54
AMS 100-011 (no. 6 021 105) for 18 ... 30 V DC, enclosure rating max. IP 65
– For connecting
two
CLVs:
AMV 30-071 (no. 1 017 391) for 18 ... 30 V DC, enclosure rating max. IP 54
AMV 200-011 (no. 6 021 106) for 18 ... 30 V DC, enclosure rating max. IP 65
– or –
Alternatively, a non-SICK Power pack with a voltage output of 18 ... 30 V DC pursuant
to IEC 742 (functional extra-low voltage) and a minimum power output of
20 W
.
Cable no. 2 020 264 (3 m) with 15-pin D Sub HD connector and one open end for
connecting the CLV to the non-SICK Power pack (supply voltage).
2.
The following operating voltages/power output values:
– AMV 60-011: 18 ... 30 V DC (to IEC 742), min. 20 W
– AMV 30-071: 18 ... 30 V DC (to IEC 742), min. 40 W
– AMV 100-011: 18 ... 30 V DC (to IEC 742), min. 20 W
– AMV 200-011: 18 ... 30 V DC (to IEC 742), min. 40 W
– AMS 60-013: 230 V AC
±
10 % 50 Hz
– AMS 60-012: 115 V AC
±
10 % 50/60 Hz
3.
Fitting cables see
Chapter 5.2.2 Prefabricated cables (overview), Page 5-2
.
4.
With external clock pulse supply via the "Sensor" switching input: a suitable reading pul-
se sensor for signaling an object with a bar code, e.g. a photoelectric reflex switch.
5.
With object distance detection via the "IN 0 ... IN 4" switching inputs: suitable sensors
for multi-stage dynamic focus control, e. g. photoelectric reflex switches.
6.
A PC (min. 80486, 66 MHz, 16 MB RAM, CD drive, a serial port (COM x), mouse (re-
commended)) with Windows 95
TM
/98
TM
, Windows NT
TM
or Windows XP
TM
.
7.
An RS 232 data connection cable with two 9-pin D Sub sockets for connecting the PC
to the terminal interface of the CLV in the Connection Module, e. g. no. 2 014 054.
Pin 2 (RxD) and Pin 3 (TxD) are crossed.
8.
An HTML browser, e. g. Netscape Navigator
TM
, or the I-ViewPro
TM
browser supplied with
the device (see
Chapter 3.1.1 Scope of delivery, Page 3-1
) for using the online help sy-
stem CLV-Setup Help.
9.
The appropriate bus connection module BMV/BMH 10 (available on request) for con-
necting the CLV to the Interbus-S, Profibus DP, the Device Net or to Ethernet.
10. For connection of the CLV to the CAN Scanner Network: the Operating Instructions
“
Application of the CAN interface
“ (no. 8 009 180, English edition).