Chapter
6
Operating Instructions
CLV 45x Bar Code Scanner
6-30
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 139/K949/06-06-2002
Operation
6.6
Messages of the CLV
The CLV outputs system, warning and error messages in English in response to the actions
carried out by the user for the firmware. The messages are output in plain text via the
terminal interface only.
6.6.1
Displaying messages
Proceed as follows in order to display messages on the screen of the PC in the CLV-Setup
user interface:
1.
Click on
in the toolbar.
The terminal emulator window opens.
2.
Click on the E
XTENDED
radio button in the T
ERMINAL
MODE
section.
The CLV then outputs messages in response to events that occur while the bar code is
being read. The messages are only output in the
extended mode
of the terminal emulator!
6.6.2
System messages
System messages confirm that an action has been carried out successfully, e. g. changing
the operating mode. No further messages are required.
Chapter 10.3 System messages, Page 10-19
explains the contents of the messages.
6.6.3
Warnings
Warning messages indicate that it was not possible to perform an action or that the values
set for the parameters can cause an error while the bar code is being read.
lists the warning messages in alphabetical order together with the associated
corrective measures.
6.6.4Error messages
Error messages indicate the following types of error:
•
A device defect
•
Incorrect parameter settings
•
Errors during data transmission to the host
Chapter 8.3 Error messages, Page 8-2
lists the messages in alphabetical order together
with the associated corrective measures.
Message
Meaning
Remedy
"Warning: Master Timeout"
The duration of the selected master timeout is
too short
Optimize the master timeout using the D
EVICE
CONFIGURATION
tab card in the user interface of
CLV-Setup. Download to the CLV!
(also refer to the special
Technical information
"Master/Slave with bar code scanners of CLV
Series", No. 8 007 675, English edition
)
Table 6-10: Warning