Operating Instructions
Chapter
10
CLV 45x Bar Code Scanner
Appendix
8 009 139/K949/06-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
10-21
5.
Please read the Readme file that contains the latest information and problems regar-
ding CLV-Setup.
6.
Confirm the final installation message by clicking on "OK".
7.
Restart the PC.
If necessary DLL files are updated in Windows.
The "CLV-Setup" software and the "CLV-Setup Help" online help are installed and ready.
The program logs all of the files that are installed to the "Install.log" file. This list is used by
the uninstaller to remove CLV-Setup and must not be deleted if you want to use the unin-
staller at some time in the future.
Updating an installation
There are two ways of installing a new version of CLV-Setup:
•
You can install the new version and still keep the old version (parallel installation)
– or –
•
Installation of the new version instead of the old version (overwriting)
Installation of the new version in addition to the old version
If you want to install the new version and still keep the old version of CLV-Setup, follow the
procedure described under Initial installation. When the program asks you for the target di-
rectory, you must specify a
new directory
. Both versions of the software are then available
but must not be started simultaneously.
The configuration files "*.scl" of the old version can be used in the new version and contain
the CLV parameter records. In order to do so copy the configuration files from the "data"
directory of the old version to the "data" directory of the new version.
Installation of the new version instead of the old version
When the new version is installed instead of the old one, the files of the old version first have
to be removed – with the exception of the configuration files "*.scl". They contain the para-
meter records of the CLV.
The uninstaller of the old version removes the program files. You can use the uninstaller to
remove either all of the files (with the exception of the configuration files) or only selected
files. The default setting is the complete removal (the configuration files are not removed).
In the case of user-specific removal the files are listed and only the selected files are remo-
ved. If you choose this removal method, ensure that the main directory containing the con-
figuration files "*.scl" is not deleted. We recommend that you move these files beforehand
to a different directory and copy them back to the "data" directory later.
1.
Select the Uninstaller for CLP Setup in the start menu of Windows under P
ROGRAMS
.
The Uninstaller starts and guides you step-by-step through the removal procedure with
screen messages.
2.
Select the type of removal (complete or user-specific).
3.
The new version of CLP-Setup is installed as described under
. Select
the same directory.
The new version of CLV-Setup is installed. The configuration files of the old version can con-
tinue to be used.