Chapter
10
Operating Instructions
CLV 45x Bar Code Scanner
10-42
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 139/K949/06-06-2002
Appendix
a) Dynamic teach-in procedure
Configuring the dynamic teach-in procedure:
•
Accompanying measure: Changing the reading pulse for teach-in
1.
Select the D
EVICE
CONFIGURATION
tab card.
2.
Click on the D
YNAMIC
option in the T
EACH
-
IN
section.
3.
Select the M
ATCH
CODE
TEACH
-
IN
option in the list field in the A
SSIGNMENT
SENSOR
2 section.
4.
If necessary, proceed as follows to activate the output filter in the C
ODE
COMPARISON
sec-
tion:
– Click on the C
ODE
#1
ACTIVE
check box.
– Click on the O
UTPUT
FILTER
check box.
– Click on the C
ODE
#1
ACTIVE
check box again.
The permanent activation of the code comparison is de-activated again. However,
the output filter remains active.
5.
Click on the E
DIT
READING
TRIGGER
command button.
6.
Click on the S
ERIAL
INTERFACE
radio button in the dialog button under M
ODE
.
7.
Click on the E
DIT
RESULT
OUTPUTS
command button.
8.
Select the M
ATCH
1 option in the list field in the dialog box under O
UTPUT
FUNCTIONS
for
Result 2 ("Result" LED).
9.
Select the C
ODE
CONFIGURATION
tab card.
10. In the C
ODES
section activate the code type which corresponds to the match code.
11. Click on the E
DIT
CODES
command button.
12. Select the corresponding tab card of the code type and click on the F
REE
radio button
in the C
ODE
LENGTH
section.
13. Carry out the download to the CLV. To do so, click on
in the toolbar.
The D
OWNLOAD
PARAMETERS
dialog box is opened.
14. Confirm the dialog box with the saving option P
ERMANENT
.
Carrying out the dynamic teach-in procedure:
1.
Click on
in the toolbar.
The terminal emulator is opened. The CLV is in the Reading mode.
2.
Close the switch
in order to energize the "Sensor 2" switching input.
3.
Click on the P
ARAMETERIZE
radio button under D
EVICE
MODE
.
The CLV switches to Parameterize mode.
4.
Click on the R
EADING
MODE
radio button under D
EVICE
MODE
.
The CLV starts the Reading mode again and samples the state of the "Sensor 2" swit-
ching input. At the same time it activates the code comparison.
– or –
As an alternative to steps 3 and 4, switch the supply voltage to the connection module (of
the CLV) off and on again. The CLV outputs two consecutive acoustic signals to indicate that
it has switched to Reading mode.
5.
Open the switch
to de-energize the "Sensor 2" switching input.
The CLV activates the teach-in mode for match code 1.
6.
Click on the SW-T
RIGGER
ON
command button or press [F7].
The CLV starts the read port and waits for the match code.
7.
Present the match code.