Note
If a large amount of data is being read in at high speed and with a high transmission rate,
the host interface’s data traffic may not longer be completely displayed on the terminal in-
terface (display: " ... "). This is due to the slower transmission rate of the terminal interface
(9 600 bits/s).
In the default setting the CLV only sends the data contents of the bar code in the data output
string of the host interface.
The header, separator and terminator are empty.
Hint
The structure of the data output string of the host interface can be configured via the D
ATA
STRINGS
tab card. Up to 10 elements, consisting of constants and/or reading diagnosis data,
can be entered in the header, in the separator and in the terminator.
1.
Select the D
ATA
STRINGS
tab card.
2.
Click on the H
EADER
list field.
The E
DIT
PARAMETER
: TFH dialog box is opened.
3.
Click on the desired constants or placeholders for the reading diagnosis data.
The selected elements appear in the text line at the top of the dialog box in the
sequence in which they were selected.
4.
Confirm the dialog box with "OK".
5.
Repeat this procedure for the separator and terminator.
6.
Carry out the download to the CLV. To do so, click on
in the toolbar.
The D
OWNLOAD
PARAMETERS
dialog box is opened.
7.
Confirm the dialog box with the saving option P
ERMANENT
.
The CLV outputs the selected elements in the data output string of the host interface
with the next read result.
Fig. 6-13:
CLV-Setup: Output of the read result of the host interface in the terminal emulator at the
beginning (in this case: O = Output)