Operating Instructions
Chapter
3
CLV 45x Bar Code Scanner
Product description
8 009 139/K949/06-06-2002
©
SICK AG · Division Auto Ident · Germany · All rights reserved
3-9
3.3.3
Function of the beeper (buzzer)
The beeper signals the successful execution of device functions and any malfunctions
by means of differing sequences and lengths of sounds (
). For information on
troubleshooting please refer to
Chapter 8.5 Troubleshooting, Page 8-6
.
In the default setting the beeper is activated and displays the "Good Read" result status for
reading mode. The further description in these operating instructions assumes that the
beeper is operated in reading mode in the default setting.
The sound opening of the beeper is positioned on the rear narrow device end concealed
under the LED labeling.
HINT
The behavior of the beeper in
reading mode
can be modified by means of the D
EVICE
CON
-
FIGURATION
tab card of the user interface of CLV-Setup.
ON/OFF:
¾
In order to switch off the beeper, click on the B
EEPER
ACTIVE
check box in the R
ESULT
OUTPUT
section in order remove the check mark.
Output function for the result status:
1.
Click on the E
DIT
RESULT
OUTPUTS
command button in the R
ESULT
OUTPUT
section. The E
DIT
RESULT
OUTPUTS
dialog box is displayed.
2.
Click on the B
EEPER
list box in the R
ESULT
FUNCTIONS
section.
The list with the selectable functions for the result status is displayed.
3.
Click on the desired function and confirm the dialog box with OK.
4.
Carry out the download to the CLV. To do so, click on
in the toolbar.
The D
OWNLOAD
PARAMETERS
dialog box is opened.
5.
Confirm the dialog box with the saving option P
ERMANENT
.
The CLV operates the beeper with the selected values for the function of the result status
display.
Operating mode/function
Sequence of sounds
Function of the beeper
Start
Beep
•
Signals after activation that the self-test was successful
Reading mode
Beep Beep
•
Confirms starting of the reading mode after the activation and after
the waiting time of 5 s for reading the Profile bar codes has passed
Beep
•
Confirms a successful reading ("Good Read"; default setting) and
the output of the read result
Profile programming
Start Auto Setup
Beep
•
Confirms successful reading of the Profile bar code for starting/
ending the Auto Setup
Beep Beep
•
Confirms successful reading of the application-specific bar code
and starting of the reading mode.
Beep (long sound)
•
Signals that the application-specific bar code was not read
Profile programming
Beep
•
Confirms successful reading of the Profile bar code
Beep Beep
•
Confirms starting of the reading mode 10 s after reading the last
Profile bar code
Exceeding of the laser timeout
Beep Beep Beep
•
Signals de-activation of the laser diode after the laser timeout of
10 min (default setting) has been exceeded in reading mode.
However, the reading pulse is not terminated.
Table 3-3: Function of the beeper