MOUNTING TO THE CONTROL PANEL CMT-240-K
2. Mounting to the control panel
2.1 Site selection
Mount the units in a place with:
(1) A minimum of dust, and an absence of corrosive gases.
(2) No flammable, explosive gases
(3) No mechanical vibrations or shocks.
(4) No exposure to direct sunlight, an ambient temperature of 0 to 50 (32 to 122 )
that does not change suddenly.
(5) An ambient non-condensing humidity of 35 to 85%RH.
(6) The units away from large capacity electromagnetic switches or cables
through which large current is flowing.
(7) No water, oil or chemicals or where the vapors of these substances can come into
direct contact with the unit.