Shindaiwa Limited
POWERCENTER 15
Four Ashes, Wolverhampton, UK
PC15-OM-Vs: 1
T: +44 (0)1902 791855
(4)
Cleaning/Replacing the Fuel Strainer
Cleaning
1st time: 50 hours
2nd time and after: Every 100 hours
Replacement
Every 400 hours
1)
Turn the fuel lever to "CLOSE".
2)
Turn the retainer ring to the left and
remove the cup and element.
3)
Remove any water or foreign material
from the cup and clean the element using
compressed air.
(
Or replace the
element.
)
4)
Install in the reverse order of removal.
<
Note
>
Check that no foreign material is adhering to the packing then install the cup.
After installation, turn the fuel lever to "OPEN" and check that there is no fuel leakage.
After checking, turn the fuel lever to "CLOSE".
Element part no: 16271-43561 (Kubota part no.)
(5) Draining Water from the Fuel Tank
Draining
Water
Every 200 hours
1)
Remove the fuel drain plug.
2)
Drain the water and tighten the fuel drain
plug.
<Note>
Replace the packing with a new part each time you drain the water.
Packing part no.: 6C090-58961 (Kubota part no.)
Always be sure to check that there is no fuel leakage after tightening the fuel drain plug.
Retainer
Ring
Element
Close
Open
Fuel
Lever
Fuel Drain Plug
-38-