Shindaiwa Limited
POWERCENTER 15
Four Ashes, Wolverhampton, UK
PC15-OM-Vs: 1
T: +44 (0)1902 791855
15
Adjust V-belt Tension
1st
time
●
2nd time
and after
●
16
Replace V-belt
●
Or
2years
17
Clean Radiator Fin
(External)
●
18
Clean Radiator
(Internal)
●
19
Replace Fuel/Cooling
Water/Oil Hoses and
Anti-Vibration Rubber
●
Or
2years
Inspection Item
Pre-
Operation
Inspection
Inspection Period
50
hours
Every
100
hours
Every
200
hours
Every
400
hours
Every
1,000
hours
Every
2,000
hours
20
Adjust/Lap Clearance of
Air Intake/Release
Valves
●
Adjust-
ment
●
Lapping
21
Inspect/Adjust Clearance
of Fuel Injection Valves
●
22
Inspect/Adjust Fuel
Injection Pump
●
23
Clean/Inspect Spill
Containment
●
Or
1years
(1) Changing the Engine Oil
1st time
50 hours
2nd time
and after
Every 100 hours
1)
Remove the oil plug.
2)
Remove the oil drain plug and drain the
engine oil.
3)
Tighten the oil drain plug.
4)
Add oil through the oil inlet, while
checking the oil level using the oil
gauge, until it reaches the maximum
level. (Fill with approx. 3.6 L.)
5)
Tighten the oil plug.
<Note>
Refer to section "7-1. Engine Oil Inspection" for the types of engine oil.
Replace the packing of the oil drain plug with a new part each time the oil is changed.
Packing part no.: 6C090-58961 (Kubota part no.)
After tightening the oil drain plug, operate the engine for a short period and check that
there is no oil leakage. Stop the engine when completed.
Oil Plug
Oil Inlet
Oil Drain Plug
Oil Gauge
-36-