Shindaiwa Limited
POWERCENTER 15
Four Ashes, Wolverhampton, UK
PC15-OM-Vs: 1
T: +44 (0)1902 791855
7-5
.
Inspection for Fuel/Oil/Cooling Water Leakage
Warning: Fire
Absolutely never use the equipment if there is a fuel, oil or cooling water leak, and be
sure to always repair the leak before using.
Open the side door and check for fuel leakage from fuel line joints and similar components,
and check for oil and cooling water leakage. Open the fuel tap to perform inspection and
close it after inspection has been completed.
7-6
.
Battery Inspection
Warning: Injuries to Eyes and Skin
Use protective gear, such as rubber gloves, when inspecting or replacing the battery
due to the dilute sulphuric acid in the battery fluid. Be sure that fluid does not get into
eyes, or on skin or clothing.
If battery fluid gets into the eyes, or on the skin or clothing, immediately wash with a
large amount of water, and always be especially sure to seek medical attention if it
gets into the eyes.
Warning: Explosion
Do not operate the equipment or recharge the battery when the battery fluid level is
below the lower level.
Do not generate any sparks near the battery and do not allow any fire or other open
flame near the equipment because the battery generates ignitable gas.
1)
Inspect the battery fluid level. If it is near the lower level,
add distilled water until it reaches the upper level.
2)
Inspect for loose terminals and retighten if loose.
<Note>
It is necessary to recharge the battery when the specific gravity of the battery fluid is 1.23
or less. Contact the retail outlet where the equipment was purchased if this occurs.
■
Battery Replacement Procedures
1)
Remove the "
-
" (negative) cable.
(
Always be sure to first remove the "
-
"
(negative side.
)
2)
Remove the battery hold-down clamp.
3)
Remove the "
+
" (positive) cable.
4)
Remove the battery.
* Install the battery by performing the above procedures in reverse order.
(
Always be sure
to first attach the "
+
" (positive) side.
)
<Note>
Use the specified battery.
<
46B24L
>
(Japanese Industrial Standard)
UPPER
Level
LOWER
Level
Terminal
"
-
" Post
with Cap
Hold-Down
Clamp
"
+
" Post
with Cap
-28-