6-2.Connecting Load Cables
WARNING : ELECTRIC SHOCK
Do not touch the equipment during operation if the equipment or your body
is wet.
Be sure to stop the engine whenever touching output terminals such as
when installing or removing cables.
Do not connect cable to any part other than output terminals.
Do not insert any metal objects, such as pins or wires, into AC output
terminal or receptacles.
Always be sure to turn off all breakers before installing or removing devices
using AC output receptacles.
Close the output terminal cover before use.
CAUTION : FIRE
Never directly connect the generator output to commercial power supply.
< NOTE >
When connecting a load, check that the generator output terminal or receptacles connection
position are matching.
Use proper tools when connecting a load to sufficiently tighten the connection. Failure to
sufficiently tightened will result in cable burnout.
(1)
Three-Phase Output Terminal
For three-phase load:
Terminal voltage is 415 V.
For single-phase load:
Terminal voltage is 240 V.
Load
Load
Load
Load
-21-