- 13 -
7. Be sure to set the AC output switch to [OFF] position before starting the engine.
(3) The Earth Leakage Circuit Breaker has activated
When the Earth Leakage Circuit Breaker has activated, the ELCB indicator button
(White) will be out and the ELCB switch will have moved to the middle position.
In this case, stop the engine, trace the earth leakage fault and repair.
After repairing the leakage fault, reset the ELCB using the following procedure.
Push the ELCB switch down to [OFF] position.
Lift the ELCB switch to return to the [ON] position.
6. Operation
6-1. Initialization/Pre-check
(1) Checking Engine Oil
Position the equipment on a flat and stable surface, Open the oil maintenance cover and
insert the oil gauge into oil inlet to check the engine oil level (do not screw the oil gauge
into the oil tank).
Before operation, ensure oil is to upper level.
Oil Capacity: approximately 1.0 litre (maximum)
Effective Oil Volume: approximately 0.5 litre (between the LOWER and UPPER)
Warning: Electric Shock/Injuries
Be sure to disconnect all the loads to the equipment before turning the ELCB ON
again, after the earth leakage circuit breaker has activated.
Caution: Fire/Burns/Injuries
When checking the equipment, always stop the engine, and wait until the engine
cools down.
Never place the equipment close to flammable products. Maintain a minimum
clearance of 1 metre around the equipment.