5. Equipment
5-1. Earth Grounding Terminal
The grounding terminal of this equipment.
Even though all the terminals of the loads have
been grounded to the earth, this machine
grounding terminal should be grounded to the
earth.
(Grounding resistance: 500 Ω or below)
<Caution>
In the event you cannot ground the generator
to the earth, consult with the authorized
distributor or our dealer.
5-2. Frequency Changeover Switch
This Frequency Changeover Switch changes the
frequency either 50 Hz or 60 Hz.
Change the frequency:
50 Hz: Turn the frequency changeover switch
to [50 Hz].
60 Hz: Turn the frequency changeover switch
to [60 Hz].
5-3. Engine Speed Control Switch (Eco-mode)
The Eco mode is designed to control the engine
speed based on the required current to minimize
the noise level and fuel consumption. Turn the Idle
control switch to [ECO] position to use this
function.
(1) Welding
When welding current output is detected, the
engine turns to appropriate speed and returns to
idling rpm approximately 8 seconds after welding
has finished.
(2) Generator
While utilizing AC output, the engine turns to appropriate speed and returns to idling rpm
when not utilizing AC output. [HIGH] mode will always turn the engine to high rpm.
<Caution>
Always select [HIGH] mode while utilizing high load equipment to ensure constant
output.
Earth Grounding Terminal
Earth Grounding Terminal
Grounding Rod
Frequency Changeover Switch
Engine Speed Control Switch