66
4. Parameter description
Parameter
Example 2: This example shows the influence of changing the bias. When the input is 0V the output
frequency is 10 Hz. At mid-point a potentiometer will give 40 Hz. Once the Maximum
Output Frequency is reached, any further increase of the potentiometer or signal will not
increase the output frequency. (To use the full potentiometer range, please refer to
Example 3.) The value of external input voltage/current 0~8.33V corresponds to the
setting frequency 10~60Hz.
Parameter setting
:
P.38 = 60.00Hz
,
P.73 = 1
,
P.139 = 16.7%
,
P.140 = 100%
,
P.141 = 0
Example 3: This example also shows a popular method. The whole scale of the potentiometer can be
used as desired.
Parameter setting
:
P.38 = 60.00Hz
,
P.73 = 1
,
P.139 = 20.0%
,
P.140 = 83.3%
,
P.141 = 0
PDF created with pdfFactory trial version