40
3. Primary operation
Primary operation
Note: 1. In the parameter setting mode, both the indicating lamp of
and
will turn off.
2. Please make sure to hold down the
key for more than 0.5s when writing the set value of the
parameters.
3. Parameter is set as 99999and the actual counterpart of CPU value is 65535
,
therefore if setting the value
below 99999
,
CPU value will drop from 65535 gradually
,
if so
,
the operation panel should show as
65534
、
65533
……
4. As setting the parameter
,
button
is used to select above or below option
,
When the parameter
reaches 99999(0), the panel will stop at this figure
,
if there is aneed to surpass this value
,
the user must
press
button
,
and parameter value will go back to 0 or drop to 99999 gradually.
5. When parameter setting is 99999
,
for SH-PU series operation panel, they will show
“
9999
”
,
For DU
series operation panel, it will show
“
99999
”
.
3.3 The basic operation procedure for PU mode (P.79=0 or 1 )
Steps
Description
1
•
Change the operation mode to PU mode, and the indicating lamp of
will be lit.
Note: 1. When P.79=0, after the power is switched on or the inverter is reset, the inverter will
enter external mode first.
2. For selection and shifting of operation modes, please refer to Section 3.1.
2
•
Enter frequency setting mode, and write the target frequency into the memory.
Note: For the detailed setting procedure, please refer to Section 3.2.
3
•
Press
or
, then the motor will run.
•
At this time, the indicating lamp of
will flicker, indicating that the motor is
running. The DU01 operation panel then enters the monitoring mode automatically. (For
detailed descriptions, please refer to P.110 in Chapter 4.)
Note: 1. For the operating flow of monitoring mode, please refer to Section 3.2.
2. While the motor is running, the frequency setting mode is also valid, and thus the target
frequency can be changed to regulate the motor speed.
4
•
Press
STOP
RESET
, then the motor will decelerate, till it stops.
•
The indicating lamp of
will not turn off until the inverter stops outputting voltages.
3.4 The basic operation procedure for external mode (
, P.79=0 or 2)
Steps
Description
1
•
Change the operation mode to the external mode, and then the indicating lamp of
will be lit.
PDF created with pdfFactory trial version