background image

 

P a g e

 

INTRODUCTION 

Thank you for purchasing a SHEL LAB oven. We know you have many choices in today’s competitive 

marketplace when it comes to constant temperature equipment. We appreciate you choosing ours. We 

stand behind our products and will be here if you need us. 

 

R

EAD THIS 

M

ANUAL

 

Failure to follow the guidelines and instructions in this user manual may create a protection 

impairment by disabling or interfering with the unit safety features. This can result in injury or death. 

Before using the unit, read the manual in its entirety to understand how to install, operate, and 

maintain the unit in a safe manner. Keep this manual available for use by all operators. Ensure all 

operators are given appropriate training before the unit begins service. 

 

S

AFETY 

C

ONSIDERATIONS AND 

R

EQUIREMENTS

 

Follow basic safety precautions, including all national laws, regulations, and local ordinances in your 

area regarding the use of this unit. If you have any questions about local requirements, please 

contact the appropriate agencies. 

SOPs

 

Because of the range of potential applications this unit can be used for, the operator or their 

supervisors must draw up a site-specific standard operating procedure (SOP) covering each 

application and associated safety guidelines. This SOP must be written and available to all operators 

in a language they understand. 

Locations and Intended Applications Range 

SMOHP forced-air ovens are engineered for constant temperature forced-air drying, curing, and 

baking applications in professional, industrial, and educational environments. The ovens are not 

intended for use at hazardous or household locations.  

Power 

Your unit and its recommended accessories are designed and tested to meet strict safety 

requirements.  

 

Always hardwire the unit power feed to a protective earth-grounded electrical source that 

conforms to national and local electrical codes. If the unit is not grounded, parts such as 

knobs and controls may conduct electricity and cause serious injury. 

 

Position the unit so the end-user can quickly and easily disconnect or uncouple the power 

feed in the event of an emergency. 

 

Avoid damaging the power feed. Do not bend it excessively, step on it, place heavy objects 

on it. A damaged power feed can easily become a shock or fire hazard. Never use a power 

feed after it has been damaged. 

 

Use only approved accessories. Do not modify system components. Any alterations or 

modifications to your oven may be dangerous and will void your warranty. 

Содержание SMO5HP-2

Страница 1: ...Installation Operation Manual SMO5HP 2 HIGH PERFORMANCE OVEN 220 240 Voltage...

Страница 2: ...urge Port The SMO5HP 2 can be built with a 3 8 inch ID 9 5mm gas in port on the back of the oven This optional port can be connected to a cylinder of nitrogen N2 or other inert gas to purge the oven c...

Страница 3: ...S D as forced air ovens for professional industrial or educational use where the preparation or testing of materials is done at an ambient air pressure range of 22 14 31 3 inHg 75 106 kPa and no flamm...

Страница 4: ...l the Oven 17 Installation Cleaning 17 Install the Shelving 17 GRAPHIC SYMBOLS 19 CONTROL PANEL OVERVIEW 21 OPERATION 23 Operating Precautions 23 Theory of Operations 24 Put the Oven into Operation 26...

Страница 5: ...s must draw up a site specific standard operating procedure SOP covering each application and associated safety guidelines This SOP must be written and available to all operators in a language they un...

Страница 6: ...4897 extension 4 or 503 640 3000 FAX 503 640 1366 Sheldon Manufacturing INC P O Box 627 Cornelius OR 97113 ENGINEERING IMPROVEMENTS Sheldon Manufacturing continually improves all of its products As a...

Страница 7: ...through the unit access port Select thermocouples suitable for the application temperature you will be calibrating at Why Probes Reference readings taken outside the chamber using wire temperature pr...

Страница 8: ...8 P a g e INTRODUCTION...

Страница 9: ...rior and exterior If you find any damage to the unit follow the carrier s procedure for claiming damage or loss 1 Carefully inspect the shipping carton for damage 2 Report any damage to the carrier se...

Страница 10: ...ent Connect Wire Braid 14 gauge 6 inches 15 cm Intake Vent Exhaust Vent Control Panel Intake Vent Valve Control Exhaust Vent Valve Control Outer Door Gasket Chamber Ceiling Liner Left wall Chamber Lin...

Страница 11: ...TE INFORMATION Locate the data plate on the back of the oven next to the power inlet The data plate contains the oven model number and serial number Enter this information below for future reference D...

Страница 12: ...12 P a g e RECEIVING YOUR UNIT...

Страница 13: ...ual Pre Installation Check that the required ambient condition for the oven are met page 14 Check that the spacing clearance requirements are met page 14 Unit dimensions may be found on page 34 Check...

Страница 14: ...her channeling o Otherwise 24 inches 610mm of headspace clearance is required between the exhaust vent and any overhead cover or partition Do not place objects on top of the oven Exception A power exh...

Страница 15: ...required circuit breaker is 20 Amps Oven Fuses The oven is provided with two 20 amp fuses These are located in holders adjacent to the power feed braid on the back power panel of the unit The fuses pr...

Страница 16: ...fire hazard LIFTING AND HANDLING The oven is heavy Use appropriate lifting devices that are sufficiently rated for these loads Follow these guidelines when lifting the oven Lift the oven only from its...

Страница 17: ...r to cleaning and installation Do not clean with deionized water See the Cleaning and Disinfecting topic in the User Maintenance section see page 31 for more information on how to clean the oven chamb...

Страница 18: ...18 P a g e INSTALLATION...

Страница 19: ...s adjustable temperature Indique temp rature r glable AC Power Rep re le courant alternatif I ON O OFF I indique que l interrupteur est en position marche O indique que le commutateur est en position...

Страница 20: ...20 P a g e GRAPHIC SYMBOLS...

Страница 21: ...ough menus and parameters lists when programming heating recipe profiles or performing a temperature calibration On the homepage it scrolls through operating parameters or profile start The gray Reset...

Страница 22: ...22 P a g e CONTROL PANEL OVERVIEW...

Страница 23: ...ids or fuel air mixtures in quantities that can become potentially explosive Outgassed byproducts may be hazardous to or noxious for operating personnel Exhaust should be vented to a location outside...

Страница 24: ...ove the oven chamber The processor employs proportional integral derivative analytical feedback loop functions when measuring and controlling the shelving temperature PID controlled heating pulse inte...

Страница 25: ...ge options when the oven is running a constant temperature set point The intended application of the power exhaust fan is to positively vent exhaust out of the workspace around the oven The standard r...

Страница 26: ...Limit for your application page 27 Optional After setting the High Limit you may set the constant temperature set point to a warm up temperature or to your constant temperature baking set point Read...

Страница 27: ...ultiple Times Limit High Option Push the Advance button until Lh S1 Limit High Set Point shows in the green mid level display line 2 Adjust the high limit to at least 5 C above the highest temperature...

Страница 28: ...mming steps 1 Adjust the constant temperature set point on the home page Adjust Do not exceed the high limit temperature set point Note Holding down an arrow button will cause the temperature to advan...

Страница 29: ...oven chamber or hardware failure turn off the oven and wait for the oven to cool to room temperature before opening chamber door Contact Technical Support for assistance Restoring Heating Perform the...

Страница 30: ...mbly in place 2 Mount the power exhaust blower on the exhaust vent cover assembly a The open side of the blower mounting body should fit over the sliding damper b Align the blower and the assembly scr...

Страница 31: ...eel surfaces Do not use chlorine based bleaches or abrasives these will damage the chamber liner Warning Exercise caution if cleaning the unit with alcohol or flammable cleaners Always allow the unit...

Страница 32: ...ssories shelving and other non attached items from the chamber when disinfecting Disinfect all surfaces in the chamber making sure to thoroughly disinfect the corners Exercise care to avoid damaging t...

Страница 33: ...d shelf sliders from the oven 2 Unscrew the nuts located at the top of the right and left chamber walls 3 Remove the chamber gasket so that there is room to pull the ceiling liner out through the door...

Страница 34: ...often as required by your laboratory or production protocol or regulatory compliance schedule Always calibrate to the industry or regulatory standards required for your application A Suggested Calibr...

Страница 35: ...mperature display readings a If the readings are the same or the difference between the two falls within the acceptable range of your protocol the display is accurately showing the chamber temperature...

Страница 36: ...to the Temperature Calibration offset parameter a Push the green Advance button repeatedly unit i CA appears in the green mid display line and a number value in the red top line 5 Adjust the number v...

Страница 37: ...the two falls within the acceptable range of your protocol the display is accurately showing the chamber temperature The calibration procedure is now complete OR b Advance to the next step if the diff...

Страница 38: ...38 P a g e USER MAINTENANCE...

Страница 39: ...cting the recommended wall clearances of 10 of the height width and depth of the inner chamber All indications are average values typical for units produced in the series We reserve the right to alter...

Страница 40: ...5 minutes Recovery to 110 C 5 minutes after closing the door After the door has been open for 30 seconds AIRFLOW PERFORMANCE Ventilation Rates Cubic Feet per Minute 80 C Liters per Minute 80 C 7 6 215...

Страница 41: ...240V 5x20mm Requires 2 fuses 3300538 Optional Power Exhaust Blower Unit 220 240 Volt 9990741 Ordering Parts and Consumables If you have the Part Number for an item you may order it directly from Shel...

Страница 42: ...P O Box 627 Cornelius OR 97113 USA support sheldonmfg com sheldonmanufacturing com 1 800 322 4897 503 640 3000 FAX 503 640 1366...